Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.545
Filtrar
2.
Front Nutr ; 11: 1301427, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38660060

RESUMO

Background: High glycemic variability (GV) is a biomarker of cancer risk, even in the absence of diabetes. The emerging concept of chrononutrition suggests that modifying meal timing can favorably impact metabolic risk factors linked to diet-related chronic disease, including breast cancer. Here, we examined the potential of eating when glucose levels are near personalized fasting thresholds (low-glucose eating, LGE), a novel form of timed-eating, to reduce GV in women without diabetes, who are at risk for postmenopausal breast cancer. Methods: In this exploratory analysis of our 16-week weight loss randomized controlled trial, we included 17 non-Hispanic, white, postmenopausal women (average age = 60.7 ± 5.8 years, BMI = 34.5 ± 6.1 kg/m2, HbA1c = 5.7 ± 0.3%). Participants were those who, as part of the parent study, provided 3-7 days of blinded, continuous glucose monitoring data and image-assisted, timestamped food records at weeks 0 and 16. Pearson's correlation and multivariate regression were used to assess associations between LGE and GV, controlling for concurrent weight changes. Results: Increases in LGE were associated with multiple unfavorable measures of GV including reductions in CGM glucose mean, CONGA, LI, J-Index, HBGI, ADDR, and time spent in a severe GV pattern (r = -0.81 to -0.49; ps < 0.044) and with increases in favorable measures of GV including M-value and LBGI (r = 0.59, 0.62; ps < 0.013). These associations remained significant after adjusting for weight changes. Conclusion: Low-glucose eating is associated with improvements in glycemic variability, independent of concurrent weight reductions, suggesting it may be beneficial for GV-related disease prevention. Further research in a larger, more diverse sample with poor metabolic health is warranted.Clinical trial registration: ClinicalTrials.gov, NCT03546972.

3.
Heliyon ; 10(8): e29498, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38660249

RESUMO

Background: Health care professionals (HCPs) play a central role in leveraging technologies to support individuals with diabetes. This mixed-method study was completed to determine the feasibility of implementing periodic continuous glucose monitoring (CGM) in a primary care setting. Aim: This study aimed to evaluate and describe the experiences of using periodic CGM with data visualization tools in patients with type 2 diabetes to foster a person-centered approach in a primary care setting. Methods: Fifty outpatients aged ≥18 years, diagnosed with type 2 diabetes, and with a disease duration of at least 2 years were included in this study. Data were collected from April 2021 to January 2022. Patients completed a single period of sensor measurements for 28 days and a diabetes questionnaire about feelings and experiences of health care. HbA1c was also measured. A focus group interview was conducted to evaluate and describe the HCPs experiences of using periodic CGM. Results: Patients reported to HCPs that the CGM device was comfortable to wear and noted that LibreView was easy to use when scanning the sensor to obtain and visualize the glucose levels and trends. Data availability of CGM data was >70 %.Clinical observations revealed a mean reduction in HbA1c, mmol/mol from 60.06 [7.65 %] at baseline to 55.42 [7.20 %] after 4 weeks (p < 0.001). Two categories were identified: 1) Fostering dialogue on self-care and 2) Promoting understanding. Conclusions: The HCPs and participants in this study had a positive experience or viewed the implementation of periodic CGM with data visualization tools as a positive experience and appeared to be feasible for implementation in a primary care setting.

4.
Cureus ; 16(3): e56768, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38650779

RESUMO

We conducted a retrospective observational cohort study between 2020 and 2023 in 26 patients with type 1 and type 2 diabetes mellitus (DM) who were using 3-4 injections per day of insulin and were monitored by continuous glucose monitoring (CGM). The goal of this retrospective observational cohort study is to compare these two metrics in an internal medicine community primary care residency clinic. We used CGM devices, Dexcom G6 and G7, and Freestyle Libre 3. The goal was to compare the patient's hemoglobin A1c (HbA1c) taken during their clinic visit by phlebotomy as a marker for diabetic control with an estimated HbA1c glucose management indicator (GMI) derived from the 30-day CGM readings. HbA1c is derived from the blood, while the GMI value is derived from the interstitial fluid. Both parameters were taken within 30 days of each other. GMI was taken in the last 30 days. We excluded patients with known anemia, chronic kidney disease, polycythemia, cirrhosis of the liver, or metabolic dysfunction associated with steatohepatitis (MASH) because disease states can affect the measured HbA1c. Also, pregnant and African American patients were excluded. We concluded the measured HbA1c was 0.34% (4 mmol/mol) higher than the CGM-derived GMI. The relationship between factors that affect glycemic control was discussed in the article, as well as the future utilization of them in improving diabetic control and management. As the use of CGM continues to grow, addressing differences between laboratory-measured HbA1c and CGM-derived GMI is critical.

5.
Diabetologia ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38668761

RESUMO

AIMS/HYPOTHESIS: Previous studies have shown that individuals with similar mean glucose levels (MG) or percentage of time in range (TIR) may have different HbA1c values. The aim of this study was to further elucidate how MG and TIR are associated with HbA1c. METHODS: Data from the randomised clinical GOLD trial (n=144) and the follow-up SILVER trial (n=98) of adults with type 1 diabetes followed for 2.5 years were analysed. A total of 596 paired HbA1c/continuous glucose monitoring measurements were included. Linear mixed-effects models were used to account for intra-individual correlations in repeated-measures data. RESULTS: In the GOLD trial, the mean age of the participants (± SD) was 44±13 years, 63 (44%) were female, and the mean HbA1c (± SD) was 72±9.8 mmol/mol (8.7±0.9%). When correlating MG with HbA1c, MG explained 63% of the variation in HbA1c (r=0.79, p<0.001). The variation in HbA1c explained by MG increased to 88% (r=0.94, p value for improvement of fit <0.001) when accounting for person-to-person variation in the MG-HbA1c relationship. Time below range (TBR; <3.9 mmol/l), time above range (TAR) level 2 (>13.9 mmol/l) and glycaemic variability had little or no effect on the association. For a given MG and TIR, the HbA1c of 10% of individuals deviated by >8 mmol/mol (0.8%) from their estimated HbA1c based on the overall association between MG and TIR with HbA1c. TBR and TAR level 2 significantly influenced the association between TIR and HbA1c. At a given TIR, each 1% increase in TBR was related to a 0.6 mmol/mol lower HbA1c (95% CI 0.4, 0.9; p<0.001), and each 2% increase in TAR level 2 was related to a 0.4 mmol/mol higher HbA1c (95% CI 0.1, 0.6; p=0.003). However, neither TIR, TBR nor TAR level 2 were significantly associated with HbA1c when accounting for MG. CONCLUSIONS/INTERPRETATION: Inter-individual variations exist between MG and HbA1c, as well as between TIR and HbA1c, with clinically important deviations in relatively large groups of individuals with type 1 diabetes. These results may provide important information to both healthcare providers and individuals with diabetes in terms of prognosis and when making diabetes management decisions.

6.
Diabetes Ther ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38668998

RESUMO

INTRODUCTION: This study aims to define the distribution of direct healthcare costs for people with diabetes treated in two healthcare regions in Italy, based on number of comorbidities and treatment regimen. METHODS: This was a retrospective analysis using data from two local health authority administrative databases (Campania and Umbria) in Italy for the years 2014-2018. Data on hospital care, pharmaceutical and specialist outpatient and laboratory assistance were collected. All people with diabetes in 2014-2018 were identified on the basis of at least one prescription of hypoglycemic drugs (ATC A10), hospitalization with primary or secondary diagnosis of diabetes mellitus (ICD9CM 250.xx) or diabetes exemption code (code 013). Subjects were stratified into three groups according to their pharmaceutical prescriptions during the year: Type 1/type 2 diabetes (T1D/T2D) treated with multiple daily injections with insulin (MDI), type 2 diabetes on basal insulin only (T2D-Basal) and type 2 diabetes not on insulin therapy (T2D-Oral). RESULTS: We identified 304,779 people with diabetes during the period for which data was obtained. Analysis was undertaken on 288,097 subjects treated with glucose-lowering drugs (13% T1D/T2D-MDI, 13% T2D-Basal, 74% T2D-Oral). Average annual cost per patient for the year 2018 across the total cohort was similar for people with T1D/T2D-MDI and people with T2D-Basal (respectively €2580 and €2254) and significantly lower for T2D-Oral (€1145). Cost of hospitalization was the main driver (47% for T1D/T2D-MDI, 45% for T2D-Basal, 45% for T2D-Oral) followed by drugs/devices (35%, 39%, 43%) and outpatient services (18%, 16%, 12%). Average costs increased considerably with increasing comorbidities: from €459 with diabetes only to €7464 for a patient with four comorbidities. Similar trends were found across all subgroups analysis. CONCLUSION: Annual cost of treatment for people with diabetes is similar for those treated with MDI or with basal insulin only, with hospitalization being the main cost driver. This indicates that both patient groups should benefit from having access to scanning continuous glucose monitoring (CGM) technology which is known to be associated with significantly reduced hospitalization for acute diabetes events, compared to self-monitored blood glucose (SMBG) testing.

7.
Diabetologia ; 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38639876

RESUMO

AIMS/HYPOTHESIS: The aim of this study was to compare the effectiveness of stand-alone intermittently scanned continuous glucose monitoring (isCGM) with or without a structured education programme and blood glucose monitoring (BGM) in adults with type 2 diabetes on multiple daily insulin injections (MDI). METHODS: In this 24 week randomised open-label multicentre trial, adults with type 2 diabetes on intensive insulin therapy with HbA1c levels of 58-108 mmol/mol (7.5-12.0%) were randomly assigned in a 1:1:1 ratio to isCGM with a structured education programme on adjusting insulin dose and timing according to graphical patterns in CGM (intervention group), isCGM with conventional education (control group 1) or BGM with conventional education (control group 2). Block randomisation was conducted by an independent statistician. Due to the nature of the intervention, blinding of participants and investigators was not possible. The primary outcome was change in HbA1c from baseline at 24 weeks, assessed using ANCOVA with the baseline value as a covariate. RESULTS: A total of 159 individuals were randomised (n=53 for each group); 148 were included in the full analysis set, with 52 in the intervention group, 49 in control group 1 and 47 in control group 2. The mean (± SD) HbA1c level at baseline was 68.19±10.94 mmol/mol (8.39±1.00%). The least squares mean change (± SEM) from baseline HbA1c at 24 weeks was -10.96±1.35 mmol/mol (-1.00±0.12%) in the intervention group, -6.87±1.39 mmol/mol (-0.63±0.13%) in control group 1 (p=0.0367 vs intervention group) and -6.32±1.42 mmol/mol (-0.58±0.13%) in control group 2 (p=0.0193 vs intervention group). Adverse events occurred in 28.85% (15/52) of individuals in the intervention group, 26.42% (14/53) in control group 1 and 48.08% (25/52) in control group 2. CONCLUSIONS/INTERPRETATION: Stand-alone isCGM offers a greater reduction in HbA1c in adults with type 2 diabetes on MDI when education on the interpretation of graphical patterns in CGM is provided. TRIAL REGISTRATION: ClinicalTrials.gov NCT04926623. FUNDING: This study was supported by Daewoong Pharmaceutical Co., Ltd.

8.
J Diabetes Sci Technol ; : 19322968241246209, 2024 Apr 20.
Artigo em Inglês | MEDLINE | ID: mdl-38641969

RESUMO

BACKGROUND AND AIMS: The Q-Score is a single-number composite metric that is constructed based on the following components: central glycemic tendency, hyperglycemia, hypoglycemia, and intra- and interday variability. Herein, we refined the Q-Score for the screening and analysis of short-term glycemic control using continuous glucose monitoring (CGM) profiles. METHODS: Continuous glucose monitoring profiles were obtained from noninterventional, retrospective cross-sectional studies. The upper limit of the Q-Score component hyperglycemia' that is, the time above target range (TAR), was adjusted from 8.9 to 10 mmol/L (n = 1562 three-day-sensor profiles). A total of 302 people with diabetes mellitus treated with intermittent CGM for ≥14 days were enrolled. The time to stability was determined via correlation-based analysis. RESULTS: There was a strong correlation between the Q-Scores of the two TARs, that is, 8.9 and 10 mmol/L (Q-ScoreTAR10 = -0.03 + 1.00 Q-ScoreTAR8.9, r = .997, p < .001). The times to stability of the Q-Score and TIR were 10 and 12 days, respectively. The Q-Score was correlated with fructosamine concentrations, the glucose management indicator (GMI), the time in range (TIR), and the glycemic risk index (GRI) (r = .698, .887, -.874, and .941), respectively. The number of Q-Score components above the target increased as the TIR decreased, from two (1.7 ± 0.9) in CGM profiles with a TIR between 70% and 80% to four (3.9 ± 0.5) in the majority of the CGM profiles with a TIR below 50%. A conversion matrix between the Q-Score and glycemic indices was developed. CONCLUSIONS: The Q-Score is a tool for assessing short-term glycemic control. The Q-Score can be translated into clinician opinion using the GRI.

9.
J Diabetes Complications ; 38(6): 108738, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38643556

RESUMO

AIMS: We aimed to investigate the association between glycemic variability (GV) and the abnormal differentiation of T-cell subpopulations in patients with type 2 diabetes mellitus (T2DM). METHODS: In total, 108 hospitalized patients with T2DM were enrolled and divided into two subgroups (normal glycemic excursion (NGE) and high glycemic excursion (HGE)) according to their mean amplitude of glycemic excursion (MAGE) level. The MAGE was evaluated via continuous glucose monitoring for 72 h consecutively. Flow cytometry was used to determine the proportions of T cell subpopulations. RESULTS: The T helper (Th) 1 cell/Th2 cell ratio was significantly higher, and the proportion of regulatory T cells (Tregs) was significantly lower in the NGE group than in the HGE group (all P < 0.05). After fully adjusting for confounders, the MAGE was positively associated with the Th1 cell/Th2 cell ratio (ß = 0.370; P = 0.009) and negatively associated with the proportion of Tregs (ß = -0.554; P = 0.001). CONCLUSION: The MAGE was an independent risk factor for abnormally high Th1 cell/Th2 cell ratio and proportion of Tregs. Abnormal differentiation of T cell subpopulations induced by GV may impair ß-cell function, aggravate insulin resistance, and contribute to the development of diabetic complications.

10.
Artigo em Inglês | MEDLINE | ID: mdl-38644079

RESUMO

BACKGROUND AND AIMS: Sleep disorders are bidirectionally linked with eating behaviors and glucose metabolism, which could be clinically relevant in type 1 diabetes (T1D). We investigated the relationship between dietary habits and sleep quality in individuals with T1D on insulin pumps and continuous glucose monitoring (CGM). METHODS AND RESULTS: In a cross-sectional study, dietary habits (7-day food diary, EPIC questionnaire) and sleep quality (Pittsburgh Sleep Quality Index questionnaire) were assessed in 59 men and 58 women with T1D, aged 19-79 years, using CGM and insulin pump. Differences in dietary habits and blood glucose after dinner (6 h) between participants differing in sleep quality, sleep duration, and sleep onset latency were evaluated. Bad Sleepers (n = 81) were twice as prevalent as Good Sleepers (n = 36) and had a significantly higher intake of fat than Good Sleepers (dinner: 30.7 ± 10.7 vs. 24.0 ± 10.5 g, p = 0.004). Short sleepers had a significantly higher usual intake (g/1000 kcal) of coffee and tea (90.4 ± 71.7 vs. 62.0 ± 35.6), alcoholic (47.8 ± 51.1 vs. 28.9 ± 31.5) and carbonated beverages (21.8 ± 38.1 vs. 9.3 ± 17.2) (p < 0.05 for all) than Long Sleepers. Long Sleep Onset Latency was associated with a significantly higher fat intake at dinner (41.8 ± 7.4 vs. 38.1 ± 9.1 % total energy, p = 0.029) than Short Sleep Onset Latency. No significant differences in post-dinner blood glucose levels were detected between participants with good or bad sleep quality. CONCLUSION: Sleep disruption is common in T1D and is associated with unhealthy dietary choices, especially at dinner, independently of post-dinner blood glucose control.

11.
J Diabetes Sci Technol ; : 19322968241245930, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38646824

RESUMO

BACKGROUND: Insulin-naive subjects with type 2 diabetes (T2D) start basal insulin titration from a low initial insulin dose (IID), which is adjusted weekly or twice per week based on fasting plasma glucose (FPG) measurement as recommended by the American Diabetes Association (ADA). The procedure to reach the optimal insulin dose (OID) is time-consuming, especially in subjects with high insulin needs (HIN). The aim of this study is to provide a fast and effective, but still safe, insulin titration algorithm in insulin-naive T2D subjects with HIN. METHOD: To do that, we in silico cloned 300 subjects, matching a real population of insulin-naive T2D and used a logistic regression model to classify them as subjects with HIN or subjects with low insulin needs (LIN). Then, we applied to the subjects with HIN both a more aggressive insulin dose initiation (SMART-IID) and two newly developed titration algorithms (continuous glucose monitoring [CGM]-BASED and SMART-CGM-BASED) in which CGM was used to guide the decision-making process. RESULTS: The new titration algorithm applied to HIN-classified individuals guaranteed a faster reaching of OID, with significant improvements in time in range (TIR) and reduction in time above range (TAR) in the first months of the trial, without any clinically significant increase in the risk of hypoglycemia. CONCLUSIONS: Smart basal insulin titration algorithms enable insulin-naive T2D individuals to achieve OID and improve their glycemic control faster than standard guidelines, without jeopardizing patient safety.

12.
Diabetes Res Clin Pract ; 211: 111678, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38642860

RESUMO

OBJECTIVE: We evaluated the impact of intermittently scanned continuous glucose monitoring(is-CGM)over self-monitoring of blood glucose(SMBG) in the context of diabetes self-management education (DSME) in sub-optimally controlled type 2 diabetes(T2D) in a multi-ethnicsetting. RESEARCH DESIGN AND METHOD: Randomized-controlled, open-label trial (NCT04564911), of T2D with HbA1c ≥ 7.5-≤10 %, on oral agents with/without basal insulin was carried out. Intervention arm received 6 weeks(w) continuous is-CGM, followed by one is-CGM/month till 24w. Control arm was advised to perform 4 SMBG/day. Educationwas delivered at weeks 0, 2, 8, 16. PRIMARY OUTCOME: Change in HbA1c from baseline at 24w. Modified intention-to-treat (mITT) analysis with linear mixed-effect model for repeated measurementswas performed. RESULTS: 176 subjects, age 55 ± 10.7 years(y), DM duration 11 ± 7.3y, BMI 27.8 ± 5.9 kg/m2, 58 % Male, 29.5 % basal insulin users were analysed. Within each arm,from baseline to 24w, mean HbA1c decreasedby -0.6 % (-6.6.mmol/mol, p-value < 0.01)and weight decreased(isCGM: -1.44 kg; SMBG: -1.25 kg, both p < 0.01). These changes were sustained to one year. However, there wasno significant difference in these parameters between arms (p-value > 0.05). CONCLUSION: In the context of DSME, use of either SMBG or is-CGM led to improved glycaemia and reduced weight over a period of 24 weeks, sustained to one year.

13.
Bioelectron Med ; 10(1): 11, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38627825

RESUMO

BACKGROUND: Predicting of future blood glucose (BG) concentration is important for diabetes control. Many automatic BG monitoring or controlling systems use BG predictors. The accuracy of the prediction for long prediction time is a major factor affecting the performance of the control system. The predicted BG can be used for glycemia management in the form of early hypoglycemic/hyperglycemic alarms or adjusting insulin injections. Recent developments in continuous glucose monitoring (CGM) devices open new opportunities for glycemia management of diabetic patients. Many of those systems need prediction for long prediction horizons to avoid going through hypo or hyperglycemia. METHODS: In this article a nonlinear autoregressive exogenous input neural network (NNARX) is proposed to predict the glucose concentration for longer prediction horizons (PHs) than that was obtained previously with an established recurrent neural network (RNN). The proposed NNARX is a modified version from our previously published RNN with different initialization and building technique but has the same architecture. The modification is based on starting with building nonlinear autoregressive exogenous input model using MATLAB and train it, then close the loop to get NNARX network. RESULTS: The results of using the proposed NNARX indicate that the proposed NNARX is better in prediction and stability than unmodified RNN as PH becomes higher than 45 minutes. CONCLUSIONS: Modification in RNN building extends the ability of the prediction till 100 minutes. It performs statistically significant improvements in the FIT and RMSE values for 100 minutes prediction. It also decreases root mean squared error (RMSE) for both 45 and 60 minutes of prediction.

14.
J Diabetes Sci Technol ; : 19322968241242487, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629784

RESUMO

BACKGROUND: Continuous glucose monitoring (CGM) has transformed the care of type 1 and type 2 diabetes, and there is potential for CGM to also become influential in prediabetes identification and management. However, to date, we do not have any consensus guidelines or high-quality evidence to guide CGM goals and metrics for use in prediabetes. METHODS: We searched PubMed for all English-language articles on CGM use in nonpregnant adults with prediabetes published by November 1, 2023. We excluded any articles that included subjects with type 1 diabetes or who were known to be at risk for type 1 diabetes due to positive islet autoantibodies. RESULTS: Based on the limited data available, we suggest possible CGM metrics to be used for individuals with prediabetes. We also explore the role that glycemic variability (GV) plays in the transition from normoglycemia to prediabetes. CONCLUSIONS: Glycemic variability indices beyond the standard deviation and coefficient of variation are emerging as prominent identifiers of early dysglycemia. One GV index in particular, the mean amplitude of glycemic excursion (MAGE), may play a key future role in CGM metrics for prediabetes and is highlighted in this review.

15.
Front Endocrinol (Lausanne) ; 15: 1352302, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38559693

RESUMO

Blood glucose monitoring constitutes a pivotal element in the clinical management of Type 1 diabetes (T1D), a globally escalating metabolic disorder. Continuous glucose monitoring (CGM) devices have demonstrated efficacy in optimizing glycemic control, mitigating adverse health outcomes, and augmenting the overall quality of life for individuals afflicted with T1D. Recent progress in the field encompasses the refinement of electrochemical sensors, which enhances the effectiveness of blood glucose monitoring. This progress empowers patients to assume greater control over their health, alleviating the burdens associated with their condition, and contributing to the overall alleviation of the healthcare system. The introduction of novel medical devices, whether derived from existing prototypes or originating as innovative creations, necessitates adherence to a rigorous approval process regulated by the Food and Drug Administration (FDA). Diverse device classifications, stratified by their associated risks, dictate distinct approval pathways, each characterized by varying timelines. This review underscores recent advancements in blood glucose monitoring devices primarily based on electrochemical sensors and elucidates their regulatory journey towards FDA approval. The advent of innovative, non-invasive blood glucose monitoring devices holds promise for maintaining stringent glycemic control, thereby preventing T1D-associated comorbidities, and extending the life expectancy of affected individuals.


Assuntos
Diabetes Mellitus Tipo 1 , Estados Unidos/epidemiologia , Humanos , Diabetes Mellitus Tipo 1/tratamento farmacológico , Glicemia , Automonitorização da Glicemia , Qualidade de Vida , United States Food and Drug Administration
16.
Diabetologia ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568252

RESUMO

AIMS/HYPOTHESIS: Continuous glucose monitoring (CGM) provides comprehensive information on the exposure to dysglycaemia. This study aimed to investigate the threshold of hyperglycaemia related to mortality risk in critically ill patients using CGM technology. METHODS: A total of 293 adult critically ill patients admitted to intensive care units of five medical centres were prospectively included between May 2020 and November 2021. Participants wore intermittently scanned CGM for a median of 12.0 days. The relationships between different predefined time above ranges (TARs), with the thresholds of hyperglycaemia ranging from 7.8 to 13.9 mmol/l (140-250 mg/dl), and in-hospital mortality risk were assessed by multivariate Cox proportional regression analysis. Time in ranges (TIRs) of 3.9 mmol/l (70 mg/dl) to the predefined hyperglycaemic thresholds were also assessed. RESULTS: Overall, 66 (22.5%) in-hospital deaths were identified. Only TARs with a threshold of 10.5 mmol/l (190 mg/dl) or above were significantly associated with the risk of in-hospital mortality, after adjustment for covariates. Furthermore, as the thresholds for TAR increased from 10.5 mmol/l to 13.9 mmol/l (190 mg/dl to 250 mg/dl), the hazards of in-hospital mortality increased incrementally with every 10% increase in TARs. Similar results were observed concerning the associations between TIRs with various upper thresholds and in-hospital mortality risk. For per absolute 10% decrease in TIR 3.9-10.5 mmol/l (70-190 mg/dl), the risk of in-hospital mortality was increased by 12.1% (HR 1.121 [95% CI 1.003, 1.253]). CONCLUSIONS/INTERPRETATION: A glucose level exceeding 10.5 mmol/l (190 mg/dl) was significantly associated with higher risk of in-hospital mortality in critically ill patients.

17.
Eur Eat Disord Rev ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568882

RESUMO

OBJECTIVE: Going extended periods of time without eating increases risk for binge eating and is a primary target of leading interventions for binge-spectrum eating disorders (B-EDs). However, existing treatments for B-EDs yield insufficient improvements in regular eating and subsequently, binge eating. These unsatisfactory clinical outcomes may result from limitations in assessment and promotion of regular eating in therapy. Detecting the absence of eating using passive sensing may improve clinical outcomes by facilitating more accurate monitoring of eating behaviours and powering just-in-time adaptive interventions. We developed an algorithm for detecting meal consumption (and extended periods without eating) using continuous glucose monitor (CGM) data and machine learning. METHOD: Adults with B-EDs (N = 22) wore CGMs and reported eating episodes on self-monitoring surveys for 2 weeks. Random forest models were run on CGM data to distinguish between eating and non-eating episodes. RESULTS: The optimal model distinguished eating and non-eating episodes with high accuracy (0.82), sensitivity (0.71), and specificity (0.94). CONCLUSIONS: These findings suggest that meal consumption and extended periods without eating can be detected from CGM data with high accuracy among individuals with B-EDs, which may improve clinical efforts to target dietary restriction and improve the field's understanding of its antecedents and consequences.

18.
Diabetes Obes Metab ; 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38572593

RESUMO

AIMS: To compare the effects of 4 hours of laboratory-based regular activity breaks (RABs) and prolonged sitting (SIT) on subsequent 48-h free-living interstitial glucose levels in a group of healthy adults. MATERIALS AND METHODS: In this randomized crossover trial, participants completed two 4-h laboratory-based interventions commencing at ~5:00 pm: (1) SIT and (2) SIT interrupted with 3 min of body weight resistance exercise activity breaks every 30 min (RABs). Continuous glucose monitoring was performed during the intervention and for 48-h after, during which time participants returned to a free-living setting. RESULTS: Twenty-eight adults (female n = 20, mean ± SD age 25.5 ± 5.6 years, body mass index 29.2 ± 6.9 kg/m2) provided data for this analysis. During the intervention period, RABs lowered mean interstitial glucose by 8.3% (-0.47 mmol/L/4 h, 95% confidence interval [CI] -0.74 to -0.20; p = 0.001) and area under the curve (AUC) by 8.9% (-2.01 mmol/L/4 h, 95% CI -3.05 to -0.97; p < 0.001) compared to SIT. Measures of glycaemic variability were not significantly different during the intervention. There were no significant differences in mean glucose and AUC between conditions during the first nocturnal period and 24-h post intervention. When compared to SIT, RABs increased continuous overall net action of glucose at 1 h and SD glucose by 22% (0.18 mmol/L, 95% CI 0.03 to 0.29; p = 0.018) and 26% (95% CI 4.9 to 42.7; p = 0.019) in the first nocturnal period and by 10% (0.09 mmol/L, 95% CI 0.01, 0.17; p = 0.025) and 15% (95% CI 6.6 to 22.4; p = 0.001) in the 24-h post intervention period, respectively. CONCLUSION: Performing activity breaks in the evening results in acute reductions in interstitial glucose concentrations; however, the magnitude of these changes is not maintained overnight or into the following 48 hours.

19.
Diabet Med ; : e15321, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38576173

RESUMO

AIMS: To explore the feasibility and potential benefits of a peer support programme for adults with insulin-treated type 2 diabetes (T2D) starting continuous glucose monitoring (CGM). METHODS: This part of the Steno2tech study is an exploratory, single-centre, open-labelled, prospective, randomised controlled trial (RCT). A total of 60 participants were randomised 2:1 to 12 months of CGM with or without peer support. All participants received a 3-h diabetes self-management education course including a CGM part on how to use the CGM and interpret the CGM-derived data. Peer support consisted of three 3-h peer support meetings over the first 6 months of the study period with groups of three to six people. The exploratory outcomes included the acceptability and feasibility of the peer support intervention, and the between-group difference in change in several glycaemic, metabolic and participant-reported outcomes measured at baseline, 6 and 12 months. RESULTS: The peer support intervention was found acceptable and feasible. Participants shared their experiences of using and interpreting CGM data and its association with health behaviour. While both groups had improvements in glycaemic, metabolic and participant-reported outcomes, there were no significant between-group differences. CONCLUSIONS: Although feasible, we found no measured additional benefits when adding a peer support programme after starting CGM in this exploratory RCT including adults with insulin-treated T2D. Understanding the perceived effect of and preferences for a peer support intervention from the participants' points of view, including why individuals declined to participate, would be of value for future research.

20.
World J Methodol ; 14(1): 90316, 2024 Mar 20.
Artigo em Inglês | MEDLINE | ID: mdl-38577196

RESUMO

Managing diabetes during pregnancy is challenging, given the significant risk it poses for both maternal and foetal health outcomes. While traditional methods involve capillary self-monitoring of blood glucose level monitoring and periodic HbA1c tests, the advent of continuous glucose monitoring (CGM) systems has revolutionized the approach. These devices offer a safe and reliable means of tracking glucose levels in real-time, benefiting both women with diabetes during pregnancy and the healthcare providers. Moreover, CGM systems have shown a low rate of side effects and high feasibility when used in pregnancies complicated by diabetes, especially when paired with continuous subcutaneous insulin infusion pump as hybrid closed loop device. Such a combined approach has been demonstrated to improve overall blood sugar control, lessen the occurrence of preeclampsia and neonatal hypoglycaemia, and minimize the duration of neonatal intensive care unit stays. This paper aims to offer a comprehensive evaluation of CGM metrics specifically tailored for pregnancies impacted by type 1 diabetes mellitus.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...